Product Features & Benefits

These controllers are components of an online access control system linked to Norpass3 Access Control Management Software via either TCP/IP or RS485.

The CRC221-2 can be used to control access through one or two doors or barriers with read-in and read-out control , while supporting a wide range of managed access control features and a comprehensive range of interface formats. The enclosure houses 2 single-door interface modules plus an integral power supply unit.

Alternatively, for applications requiring read-in access control only, the CRC220-2 offers access through two doors or barriers with read-in control and free exit, while supporting a wide range of managed access control features and a comprehensive range of interface formats. The enclosure houses a two- door interface module plus an integral power supply unit. 

benefits

  • Easily managed using simple centralised management of data
  • Choice of mix and match module types enables cost-effective network structure
  • Support for a wide range of card formats and card reader interfaces makes it the ideal choice for enhancing an existing access control system
  • Security levels can be tailored to customer needs using optional security features
  • Improved visitor card management when used with our card capture reader
  • Meets demanding customer requirements through a choice of enclosures with tamper alarms fitted as standard plus features such as fire alarm control input, individual door alarms and configurable inputs and outputs.

Specifications

Electrical

Supply Voltage:

Enclosures: 240V AC
PCB: 12V DC

Current Requirement: 100 mA quiescent, 230 mA while reading (both readers)
Reader Supply:

 12V DC (100 mA max.) 5V DC option

Physical

Local settings:

DIP switches for setting node identity

Dimensions (mm):

PCB: 115 x 120 x 35 (H x W x D) 
Plastic enclosure: 325 x 300 x 135 (H x W x D)
Metal enclosure: 330 x 300 x 105 (H x W x D)

Cable Termination: Plug-in screw terminal blocks

Environmental

Operating Temperature: 0°C to 40°C
Storage Temperature: -20°C to 70°C
Relative Humidity: 95% non-condensing

Capacity

Sequential Mode: 65,000 sequential card numbers (0 - 19,999), 1,700 events
Random Mode: 8,000 random card numbers, 1,300 events

data communications

Management Interface:  RS485 or TCP/IP depending upon model

Inputs

Readers: 2 x 5-wire reader interfaces for Clock & Data (ABA Track 2) & Wiegand formats
Arming: 2 independent, ground activated inputs. Open-circuit arming.
Door Open Monitor: Ground activated input for monitoring door open status.
CRC220: 2 independent inputs
CRC221: 1 input
Request to Exit: Ground activated input.
CRC220: 2 independent inputs
CRC221: 1 input
Tamper Input: Ground activated input from tamper switch on housing (where applicable).

Outputs

Latch Relays: 2 independent latch relays (1 relay in CRC221) with change-over contacts rated at 2A at 30V DC.
Auxiliary Output: 2 independent open-collector outputs for auxiliary control such as card capture.
Tamper Alarm: Open-collector output (300mA), activated when tamper alarm is active.
Door Alarm: Door 1 alarm is shared with the tamper alarm output. On CR220, door 2 alarm output is a separate open-collector output (300mA).
Assignable Output: Open-collector output controlled from Norpass3 in online operation.

Cabling

CRC200 to reader: Belden 9536 or equivalent (100m maximum)
RS485 comm’s: Belden 9729 or equivalent (1,200m maximum overall length)